| Nominal battery system voltage | 12V DC |
| Inverter Output | |
| Rated power | 2000W |
| Surge power | 6000VA |
| Capable of starting electric motor | 1HP |
| Waveform | pure sine wave |
| Nominal output voltage RMS | 220V / 230V / 240V AC ±10% |
| Output frequency | 50Hz/60Hz ±0.3Hz |
| Inverter efficiency (Peak) | >88% |
| Line mode efficiency | >95% |
| Power factor | 1.0 |
| Typical transfer time | 10ms (max) |
| Input AC | |
| Voltage | 230V AC |
| Selectable voltage range | 96~132V AC 155~280V AC (for personal computers) |
| Frequency range | 50Hz/60Hz (Auto sensing) 40~80Hz |
| Battery | |
| Minimum start voltage | (10V/10.5V/11V) +0.5V |
| Low battery alarm | (10V/10.5V/11V) +0.5V |
| Low battery cut off | 10V/10.5V/11V |
| High voltage alarm | (13.8-14.5V) +1V |
| High battery voltage recover | (13.8-14.5V) +0.5V |
| Idle consumption - Search mode | Load 100±20W (220V) |
| Charger | |
| Output voltage | Depends on battery type |
| Charge AC input breaker rating | 2-3K/30A |
| Overcharge protection | 15.7V DC |
| Maximum charge current | 60A |
| Bypass protection | |
| Input voltage waveform | Sine wave (grid or generator) |
| Nominal input frequency | 50Hz or 60Hz |
| Overload protection | Circuit breaker |
| Output short circuit protection | Circuit breaker |
| Bypass breaker rating | 1-3K/30A |
| Max bypass current | 30A |
| Other specifications | |
| Dimensions(H*W*D) | 423*247*197 mm |
| Package dimensions(H*W*D) | 585*387*322 mm |
| Net weight | 21.1 kg |
| Gross weight | 24.1 kg |
| Operating temperature | 0°C to 40°C |
| Storage temperature | -15°C to 60°C |
| Audible noise | 60dB max |
| Display | LED+LCD |