| Battery voltage | 48V DC (Lithium / Lead-acid) |
| Inverter output | |
| Rated power | 6000VA / 6000W |
| Parallel capability | yes, max 6 units |
| Surge power | 12000VA |
| Waveform | pure sine wave |
| AC voltage regulation (Battery mode) | 230V AC +/- 5% @ 50/60Hz |
| Transfer time | 10ms (typical) / 20ms (max) |
| AC charger | |
| Charge current | 80A |
| Voltage | 230V AC |
| Selectable voltage range | 170~280V AC (for PC) / 90~280V AC (for home appliances) |
| Frequency range | 50Hz / 60Hz (Auto sensing) |
| Efficiency | |
| Inverter efficiency (peak) | 93% |
| Solar charger | |
| Maximum PV array open circuit voltage | 500V DC |
| MPPT range @ operating voltage | 120~450V DC |
| Number of independent MPP trackers | 2 |
| Strings per MPP tracker | 1 |
| Max. input current per MPP tracker | 16A |
| Maximum solar charge current | 100A |
| Maximum PV array power | 8000W |
| General specifications | |
| Dimensions(W*H*D) | 460*395*132 mm |
| Protection degree | IP20 |
| Net weight | 13.5 kg |
| Altitude | < 2000m |
| Operating temperature | 0°C to 55°C |
| Humidity range (non-condensing) | 5% - 95% |
| Storage temperature | -15°C to 60°C |